Brownian motion media consists of a thick fiber mesh made from ultra-fine glass or polypropylene fibers. The media is packed between reinforcing screens for strength…
Month: May 2018
Liquid/gas coalescer cartridges are similar to cartridge filters in appearance and size. The media is designed for the gas flow inside to out, thus allowing…
The basic horizontal knockout pot shown in Figure P-10 can have internals configured many different ways. As with vertical vessels, careful consideration must be given…
The maximum allowable gas velocity determines the required vapor space area above the highest liquid operating level. One method used to determine the required vapor…
Vessel length is based on liquid holding volume and residence time. The length is adjusted to achieve the necessary liquid holding volume to satisfy proper…
The distance between the outlet nozzle opening and top of the mist elimination device is recommended to be a minimum of 12 inches, increasing in…
A K factor of 0.35 will give a safe velocity for practically all applications where operating pressure is reasonably close to atmospheric. Giving account to…
Generically known as demister pads, wire mesh has been used for decades as a contacting media for coalescing liquid aerosols. First introduced as a woven…
Vane mist eliminators can be used in tandem with wire mesh pads to control the amount of liquid pooling within the pad. Contacting the bulk…
Vane Mist eliminators (sometimes referred as chevron design mist eliminators) are best used when liquid loading is high and/or the liquid is viscous or has…